landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 14751 > < Diagram Information and Instructions|Page 14749
Page 15
background image

Series-parallel circuits are very common in automobiles. Many parallel circuits in an automobile use a switch that is in series with the circuit to control
current flow. They are also used to put a load device in series to drop the voltage of the load devices in parallel. A good example of this type of
series-parallel circuit would be the instrument cluster illumination lamps and the dashboard rheostat (variable resistor). The rheostat or dimmer switch
varies the voltage to the lights.

An open in the series portion of the circuit will stop all current flow, but an open in one of the parallel branches will stop current flow in that branch but
not the circuit.

To calculate the total resistance of a series-parallel circuit, first calculate the resistance of the parallel branches. Then add that value to the resistance of
the load(s) in the series portion of the circuit.

OPEN CIRCUITS

An open circuit means that there is a break or open in the circuit and there is not a complete continuous path for the current to flow through. The open
may be caused by a break in a wire, loose connection, defective switch, defective load device, or incomplete ground. The open can be located on either
side of the load.

Diagram Information and Instructions|Page 14751 > < Diagram Information and Instructions|Page 14749