landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 661 > < Diagram Information and Instructions|Page 659
Page 3
background image

Wire length (Power & Earth Distribution only) - the length of the wire in millimetres. This can be used to locate internal harness splices; look for the
shortest wire between the joint and connector. For example, it can be seen that C574-4 is 150mm from joint A82.

Earth Distribution

The ground distribution section comprises a number of Headers and Splices tables. These are used in a similar manner to those in Power Distribution; to
narrow the search area by checking for fault symptoms in associated circuits.

Connectors

Header joints are identified by their corresponding connector number with a numbered suffix to indicate the pin-out detail of the wire, i.e. C289-1
identifies connector 289, pin number 1. Wire insulation colour is identified in the normal way. Where wires have a predominant colour with a secondary
colour stripe, the main colour is identified first, i.e. LGS - Light Green with a Slate stripe.

Line Types

This means the wire connects to another circuit.

The cup and ball symbol indicates the male and female halves of connector.

A. Plug on lead (Flylead) wired directly to the component.

Diagram Information and Instructions|Page 661 > < Diagram Information and Instructions|Page 659