Discovery II (LT) V8-4.0L (2002)
6. Remove cap nuts securing fluid pipes to actuator. Disconnect pipes and remove and discard sealing washers.
CAUTION: Always fit plugs to open connections to prevent contamination.
7. With assistance, remove bolts securing torsion bar clamps. Remove clamps and remove torsion bar and actuator.
8. Use LRT-60-009 to remove nut securing actuator push rod to long arm.
9. Remove nut and bolt securing actuator to short arm and remove actuator.