Freelander Service Procedures
BODY SEALING MATERIALS
APPLICATION EQUIPMENT
77-3-7
Cavity wax application equipment and techniques
1 Air inlet
2 Flow control (spray pattern adjustment)
3 Pressure cup (1 litre capacity). Maximum
pressure 140PSI (9.7 bar, 9.84kg/cm3)
4 Gun connector
5 Lance nipple connection
6 Flexible lance
7 Rigid directional hook wand (forward cone
spray pattern)
8 Flexible nylon lance (1100mm) with 360
°
spray
pattern
9 Rigid lance (1100mm) with 360
°
spray pattern
When re-treating wax-injected areas which have been disturbed during repairs, it is necessary to use a compressed
air spray gun with integral pressure cup and a selection of interchangeable lances.
The following points must be observed during use, according to the attachments fitted:
l
Use the rigid or flexible lance attachments with 360
°
spray dispersal when treating enclosed areas, to ensure
maximum coverage.
l
Where openings are restricted, use the hook nozzle to provide a more directional spray (e.g. inside narrow or
short box sections).
l
Spray exposed underbody surfaces directly from the gun less lance attachment and without disconnecting the
fluid coupling.