Freelander Service Procedures
MANIFOLDS & EXHAUST SYSTEMS - K SERIES KV6
REPAIRS 30-3-23
Gasket - inlet manifold - RH
$% 30.15.43
Remove
1. Disconnect battery earth lead.
2. Drain cooling system.
COOLING SYSTEM - K SERIES KV6,
ADJUSTMENTS, Coolant - drain and refill.
3. Remove fuel rail.
PETROL, REPAIRS, Fuel rail - KV6 - Non
NAS.
PETROL, REPAIRS, Fuel rail - KV6 - NAS.
4. Release clip and disconnect coolant hose from
RH inlet manifold.
5. Depress locking collar and release breather
hose from RH inlet manifold.
6. Progressively loosen and remove 7 bolts
securing RH inlet manifold to cylinder head.
7. Remove inlet manifold and gasket.
8. Remove bolt securing coolant breather hose
mounting bracket to inlet manifold and remove
bracket.
Refit
1. Clean inlet manifold and cylinder head face.
2. Position coolant/breather hose bracket to inlet
manifold, fit and tighten bolt to 9 Nm (7 lbf.ft).
3. Fit new inlet manifold gasket to cylinder head,
position inlet manifold, fit and tighten bolts to 25
Nm (18 lbf.ft).
4. Connect coolant hose to inlet manifold and
secure clip.
5. Connect breather hose to manifold and secure
into collar.
6. Fit fuel rail.
PETROL, REPAIRS, Fuel rail - KV6 - Non
NAS.
PETROL, REPAIRS, Fuel rail - KV6 - NAS.
7. Fill cooling system.
COOLING SYSTEM - K SERIES KV6,
ADJUSTMENTS, Coolant - drain and refill.
8. Connect battery earth lead.