landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Seals - inlet manifold chamber - from 03MY|Page 474 > < Seals - inlet manifold chamber - up to 03MY|Page 472
Page 391
background image

MANIFOLDS & EXHAUST SYSTEMS - K SERIES KV6

30-3-18 REPAIRS

Seals - inlet manifold chamber - from 
03MY

$% 30.15.37

Remove

1. Disconnect battery earth lead.
2. Remove vacuum enhancer.

 

 + 

 BRAKES, REPAIRS, Vacuum - 

enhancer - KV6.

3. Position absorbent cloth around fuel feed pipe 

connection to collect spillage.

WARNING: The spilling of fuel is 
unavoidable during this operation. Ensure 
that all necessary precautions are taken to 
prevent fire and explosion.

4. Pull back rubber sleeve on fuel pipe connector, 

release connector and disconnect fuel pipe 
from fuel rail pipe.

CAUTION: Always fit plugs to open 
connections to prevent contamination.

5. Release and disconnect EVAP hose from 

purge control valve.

CAUTION: Always fit plugs to open 
connections to prevent contamination.

6. Disconnect multiplug from purge control valve.

7. Non NAS models: Disconnect small vacuum 

pipe from purge control valve.

8. Non NAS models: Depress locking collar and 

release vacuum pipe from IACV housing.

CAUTION: Always fit plugs to open 
connections to prevent contamination.

9. Non NAS models: Disconnect multiplug from 

IACV.

10. Non NAS models: Disconnect multiplug from 

TP sensor.

11. Non NAS models: Depress locking collars and 

release vacuum/breather pipe from purge 
control valve and LH camshaft cover. Release 
clip securing hose to 'T' piece and remove pipe.

CAUTION: Always fit plugs to open 
connections to prevent contamination.

M30 1171

Seals - inlet manifold chamber - from 03MY|Page 474 > < Seals - inlet manifold chamber - up to 03MY|Page 472