Freelander Service Procedures
MANIFOLDS & EXHAUST SYSTEMS - K SERIES KV6
30-3-18 REPAIRS
Seals - inlet manifold chamber - from
03MY
$% 30.15.37
Remove
1. Disconnect battery earth lead.
2. Remove vacuum enhancer.
3. Position absorbent cloth around fuel feed pipe
connection to collect spillage.
WARNING: The spilling of fuel is
unavoidable during this operation. Ensure
that all necessary precautions are taken to
prevent fire and explosion.
4. Pull back rubber sleeve on fuel pipe connector,
release connector and disconnect fuel pipe
from fuel rail pipe.
CAUTION: Always fit plugs to open
connections to prevent contamination.
5. Release and disconnect EVAP hose from
purge control valve.
CAUTION: Always fit plugs to open
connections to prevent contamination.
6. Disconnect multiplug from purge control valve.
7. Non NAS models: Disconnect small vacuum
pipe from purge control valve.
8. Non NAS models: Depress locking collar and
release vacuum pipe from IACV housing.
CAUTION: Always fit plugs to open
connections to prevent contamination.
9. Non NAS models: Disconnect multiplug from
IACV.
10. Non NAS models: Disconnect multiplug from
TP sensor.
11. Non NAS models: Depress locking collars and
release vacuum/breather pipe from purge
control valve and LH camshaft cover. Release
clip securing hose to 'T' piece and remove pipe.
CAUTION: Always fit plugs to open
connections to prevent contamination.
M30 1171