landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Body - Water Leaks Into Footwell Area|Page 11698 > < Body - Water Leaks Into Footwell Area|Page 11696
Page 5
background image

2. Remove the CJB bracket: (Figure 7) Remove the four bolts.

3. Release the roof opening drain tube from the lower drain grommet. (Figure 5)

4. Remove the drain tube connector from the new drain tube (EEH500120) and discard the new drain tube.

5. Trim 25mm (1.0 in) from the end of the existing roof opening panel drain tube. (Figure 8)

6. Install the new drain tube connector into the existing roof opening panel drain tube.

7. Install the roof opening panel drain tube into the lower drain grommet.

8. Install the CJB bracket.

9. Refer to Workshop Manual (GTR) section 418-00, Module Communications Network (86.70.56), and install the CJB.

PERFORM DRAIN TUBE FLOW TEST

NOTE

Global Technical Reference (GTR) lookup sequence is as follows:

GTR Home > NAS > Model > Service Information > Model Year > Workshop Manual

1. Refer to Workshop Manual (GTR) section 501-25C ID, Body Repairs - Water Leaks, and perform a drain tube flow test, ensuring water flows from

all roof opening panel drain tubes.

Body - Water Leaks Into Footwell Area|Page 11698 > < Body - Water Leaks Into Footwell Area|Page 11696