LR3 (LA) V6-4.0L (2006)
Positive Crankcase Ventilation Valve: Service and Repair
Positive Crankcase Ventilation (PCV) Valve
Service Repair No - 17.10.14
Removal
1. Disconnect the battery ground cable.
2. Remove the engine cover.
CAUTION: Always plug any open connections to prevent contamination.
3. Remove the PCV valve.
^
Disconnect the PCV hose.
^
Disconnect the electrical connector.
^
Release the PCV valve.
^
Remove and discard the O-ring seal.
Installation
1. To install, reverse the removal procedure.
^
Clean the components.
^
Install a new O-ring seal.
^
Lubricate the seal with clean engine oil.
2. Connect the battery ground cable.