LR3 (LA) V8-4.4L (2009)
NOTE: Some fluid spillage is inevitable during this operation.
10. Disconnect the 2 coolant hoses.
^
Position a container to collect the fluid.
^
Release the 2 clips.
11. Release the sealing plate.
^
Remove the 3 bolts.
12. Remove the climate control assembly.
^
Disconnect the 2 electrical connectors.
^
Remove the 3 bolts.
Installation
1. Install the climate control assembly.
^
Tighten the bolts to 10 Nm (7 ft. lbs.).
^
Connect and secure the electrical connectors.
2. Install the sealing plate.
^
Tighten the bolts to 10 Nm (7 ft. lbs.).
3. Connect and secure the coolant hoses.
^
Secure the clips.
^
Remove the hose clamps.
4. Connect the A/C pipes.
^
Clean the component mating faces.
^
Install the O-ring seals.
^
Tighten the 2 bolts to 10 Nm (7 ft. lbs.).
5. Install the heat shield.
^
Tighten the 4 nuts.