LR3 (LA) V8-4394cc 4.4L (2005)
Condenser HVAC: Service and Repair
Condenser Core
Service Repair No - 82.15.07
Removal
NOTE: The receiver drier need only be changed under the following circumstances: There is dirt in the refrigerant circuit ( eg. compressor seizure ). The
system is leaking and refrigerant has been lost to atmosphere. Refrigerant circuit has been open more than 24 hours due to repair.
1. Disconnect the battery ground cable.
2. Recover the A/C refrigerant.
3. Disconnect the A/C pipes.
^
Remove the 2 bolts.
^
Discard the O-ring seals.
^
Install blanking caps to the exposed ports.
4. Remove the viscous fan drive coupling pulley.
5. Remove the lower fan shroud.
^
Release 2 clips from the cooling fan lower shroud.
^
Release and remove the cooling fan lower shroud from the cooling pack.
6. Remove the radiator securing pegs.