landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Recall - A/T Fluid Water Contamination|Page 1815 > < Recall - A/T Fluid Water Contamination|Page 1813
Page 6
background image

2.

Locate end of transmission breather tube clipped to the edge of the transmission pan. (Figure 4)

3.

Inspect the end of the tube for blockage or damage.

4.

Unfasten clip from transmission.

5.

Guide the end of the breather tube up over the top of the transmission housing.

6.

Locate the white three-hole tube-locating clip near the top of the transmission housing.

7.

Spray a small amount of silicon lubricant on the breather tubing near the locating clip.

CAUTION

The orientation of the breather pipes is slightly different on Range Rover and Discovery Series II vehicles. On Discovery Series II vehicles
observe the following:

^

The Transfer Gearbox breather and the Transmission breather come from opposite sides of the vehicle. Movement of the white
tube-locating clip is limited by the divergence of the tubes.

^

The breather is secured to an electrical harness and must be released from that restraint.

^

Care must be exercised to avoid crimping or deforming the tubing.

8.

On Range Rover vehicles slide the white locating tube clip toward the rear of the vehicle until it stops against the bulge at the end of the
repositioned drain tube. (Figure 1)

9.

On Discovery Series II vehicles perform the following:

^

Snip the cable tie to release the breather tube from the electrical harness.

^

Slide the white locating tube clip toward the rear of the vehicle until resistance is met because of the divergence of the transmission and
transfer box tubes. (Figure 2)

^

Verify that the end of the breather tube is parallel with the outgoing AT breather and pointed toward the LH rear of the vehicle.

10.

Wipe any residual silicon lubricant from tubes.

NOTE

The fluid testing process must be followed carefully to avoid unnecessary loss of AT fluid. Done with care and with the proper tools, approximately
100 cc (3-4 oz.) of fluid can be drained for evaluation. You must have approximately two inches of fluid in the bottom of your container when the
fluid sample is taken.

WARNING

Fluid drained from the sump pan may be "hot". Exercise care when draining the fluid.

11.

Test the fluid to determine the presence of water contamination as follows:

 

^

Obtain a clean, clear glass container about three inches in diameter and about 6 inches tall.

^

 Using a 5 mm Allen wrench, break the seal on the transmission drain plug.

Recall - A/T Fluid Water Contamination|Page 1815 > < Recall - A/T Fluid Water Contamination|Page 1813