landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Air Cleaner Assembly - From 97MY|Page 1793 > < Drive Belt|Diagrams|Page 1787
Page 1
background image

Air Cleaner Housing: Service and Repair
Air Cleaner Assembly - From  97MY

Service repair no - 19.10.01

Remove

1. Release 2 clips securing mass air flow (MAF) meter to air cleaner.
2. Release MAF meter from air cleaner. Remove and discard 'O' ring from MAF sensor.
3. Disconnect multiplug from air temperature sensor.
4. Remove bolt securing air suspension air dryer to air cleaner.
5. Release air dryer from air cleaner and position aside.
6. Release air cleaner from 2 valance grommets.
7. Remove air cleaner from inner wing grommet.

Do not carry out further dismantling if component is removed for access only.

8. Remove air temperature sensor from air cleaner.
9. Remove and discard air temperature sensor seal.

10. Fit new seal to air cleaner.
11. Fit air temperature sensor to air cleaner and tighten to 8 Nm. (6 lbf. ft)

Refit

12. Fit air cleaner lugs to inner wing and valance grommets. Ensure lugs are fully engaged to grommets.
13. Position air dryer to air cleaner, fit bolt and tighten to 8 Nm. (6 lbf. ft)
14. Connect multiplug to air temperature sensor.
15. Fit new 'O' ring seal to MAF meter.
16. Engage MAF meter to air cleaner and secure with clips.

Air Cleaner Assembly - From 97MY|Page 1793 > < Drive Belt|Diagrams|Page 1787