Fuel Level Sensor: Description and Operation

Fuel Level Sensors

The sensor is a Magnetic Passive Position Sensor (MAPPS) which provides a variable resistance to ground for the output from the fuel gage. The sensor
is sealed from the fuel preventing contamination of the contacts, increasing reliability. The front and rear fuel level sensors are connected to the external
electrical connector on the flange via the connectors on the underside of the fuel pump module flange.

The front and rear sensors are attached to the carrier and are accessible via the fuel pump flange aperture.

NOTE: When a service replacement tank is ordered the tank is supplied with the front and rear level sensors fitted

The sensor comprises a series of 51 film resistors mounted in an arc on a ceramic surface. The resistors are wired in series with individual contacts. A
soft magnetic foil with 51 flexible contacts is mounted a small distance above the film resistors. A magnet, located below the ceramic surface, is attached
to the sender unit float arm. As the float arm moves, the magnet follows the same arc as the film resistors. The magnet pulls the flexible contacts onto the
opposite film resistor contacts forming an electrical circuit.

Sensor Operating Principle

The film resistors are arranged in a linear arc with resistance ranging from 51.2 to 992.11 Ohms. The electrical output signal is output proportional to
the amount of fuel in the tank and the position of the float arm. The measured resistance is processed by the instrument cluster to implement an anti-slosh
function. This monitors the signal and updates the fuel gage pointer position at regular intervals, preventing constant pointer movement caused by fuel
movement in the tank due to cornering or braking.

A warning lamp is incorporated in the instrument cluster and illuminates when the fuel level is at or below 10 liters (2.64 US gallons).

The fuel level sender signal is converted into a CAN message by the instrument cluster as a direct interpretation of the fuel tank contents in liters. The
ECM uses the CAN message to store additional OBD P Codes for misfire detection when the fuel level is below a predetermined capacity.

Front Fuel Level Sensor Resistance/Fuel Gage Read out Table

NOTE: These figures are with the vehicle on level ground. Sensor readings will differ with varying vehicle inclinations.

Sender Unit Resistance, Ohms

Nominal Gage Reading

51

Empty

84

Low fuel level illumination (12.5L)

375

Half full

911

Full

Rear Fuel Level Sensor Resistance/Fuel Gage Read out Table

NOTE: These figures are with the vehicle on level ground. Sensor readings will differ with varying vehicle inclinations.

Sender Unit Resistance, Ohms

Nominal Gage Reading

86

Empty

160

Low fuel level illumination (12.5L)

441

Half full

944

Full