background image

^

After disconnection of any cables, carefully install appropriate dust caps to protect the mating faces of the connectors from damage or
contamination.

^

Avoid introducing tight bends (less than 30 mm radius) or kinks into the fibre optic cable during service or repair. Tight bends or kinks could
impair operation, cause immediate system failure, or future system failure.

^

Avoid excessive force, strain or stress on the fibres and connectors, especially permanent stress after reinstallation.

Understanding the Circuit Diagrams

Understanding The Circuit Diagrams

Components

After each component description, a translation code is displayed in brackets, for example: Starter relay (R102), Engine control-module (ECM)(D131).
The codes can be ignored. 

NOTE:  A dotted outline indicates that the component identified is not shown in its entirety.

Connectors 
Connectors and header joints are identified by their corresponding connector number with a numbered suffix to indicate the pin-out detail of the wire, i.e.
C0292-1 identifies connector 292, pin number 1. Wire insulation colours are listed in a table at the end of this section. Where wires have a predominant
colour with a secondary colour tracer, the main colour is identified first, i.e. WH-BK - white with a black tracer.

Wire length (Power and Ground Distribution only)

The wire length (in millimeters) is displayed after the colour and cross sectional area; for example, SR,0.35,480. In this example, the figure, 480
indicates the approximate position of the harness splice is 480mm from connector C2335.

Line Types

Crossed wires as illustrated above show an example of how a twisted pair of wires may be represented on the circuits.

The arrows illustrated above show an example of the page break symbols, identifying that the circuit continues at the corresponding letter on the sheet
number indicated.

The cup and ball symbol represents the male and female halves of connector. Most connectors plug directly into a component but some are wired directly
to the component using a 'flylead' as with C0503 above. 

Ground points 
Ground points are identified with an eyelet symbol and a connector number, except where components are grounded through its fixings, when only the
eyelet is shown.

Colour Codes