ES 300 V6-3.0L (3VZ-FE) (1992)
Mass Air Flow Meter: Service and Repair
Air Cleaner Hose
Removal
1.
DISCONNECT CABLE FROM NEGATIVE TERMINAL OF BATTERY
CAUTION (W / Airbag): Work must be started after approx. 30 seconds or longer from the time the ignition switch is turned to the LOCK
position and the negative (-) terminal cable disconnected from the battery.
2.
DISCONNECT COIL CORD CLAMP
3.
DISCONNECT VOLUME AIR FLOW METER CONNECTOR
4.
DISCONNECT AIR CLEANER HOSE
5.
REMOVE AIR CLEANER CAP AND VOLUME AIR FLOW METER ASSEMBLY
Air Flow Meter
6.
REMOVE VOLUME AIR FLOW METER FROM AIR CLEANER CAP
(a)
Remove the screw and wire bracket.
(b)
Remove the bolt, two screws and bracket.
Lock Plate
(c)
Pry off the lock plate, and remove the four nuts, lock plate, volume air flow meter and gasket.
Installation