lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Radiator Cooling Fan Control Module|Locations|Page 2810 > < Radiator Cooling Fan Control Module|Locations|Page 2808
Page 2
background image

(e)

Inspect the input signal and output current.

NOTICE:  Be sure to perform the inspection with the radiator coolant temperature less than 95°C (203°F).

(1) Connect the 400 A probe of the ammeter to terminal M+ of the cooling fan motor.
(2) Set the intelligent tester to the oscilloscope function.
(3) Using the intelligent tester, check the waveform between terminals RFC and E1 of the ECM. 

Standard waveform

HINT:  
^

If the input signal is abnormal, there is a malfunction in the ECM or cooling fan ECU.

Radiator Cooling Fan Control Module|Locations|Page 2810 > < Radiator Cooling Fan Control Module|Locations|Page 2808