lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Circuit Operation|Page 1136 > < Diagram Information and Instructions|Page 1133
Page 1
background image

Radiator Cooling Fan Motor: Description and Operation
Circuit Operation

1.HEATER BLOWER OPERATION

Manual Blower Operation
When the blower control SW is set to any blower speed, the A/C control assembly operates and the current to drive the blower motor flows from 
TERMINAL BLW of the A/C control assembly to TERMINAL SI of the blower motor control relay. The current activates the  relay and the
voltage applied to TERMINAL +B of the blower motor control relay is output at TERMINAL M+ as the voltage for the selected blower speed.
The current then flows from TERMINAL M+ of the blower motor control relay to TERMINAL 2 --> TERMINAL 1 --> TERMINAL M- of
blower motor control relay --> TERMINAL GND --> GROUND, and the blower motor operates at the blower speed selected.

Auto function
When the auto SW is turned ON, the A/C control assembly calculates the required vent temperature based on the set temperature and input from
each sensor. Then TERMINAL BLW of the A/C control assembly inputs current to TERMINAL SI of the blower motor control relay in
conformity with the required vent output. This current activates the blower motor control relay so that current flows from TERMINAL M+of the
blower motor control relay --> TERMINAL 2of blower motor --> TERMINAL 1--> TERMINAL M-of blower motor control relay 
TERMINAL--> GND --> GROUND, activating the blower motor. The blower motor then operates at different steps in conformity with variable
current flow output from TERMINAL BLW of the A/C control assembly to TERMINAL SI of the blower motor control relay.

2.

OPERATION OF AIR INLET CONTROL SERVO MOTOR
(switching from fresh to Recirc)
With Ignition SW turned ON, the current flows from GAUGE fuse to TERMINAL IG of A/C control assembly -->TERMINAL AIR -->
TERMINAL 2
 of air inlet control servo motor --> TERMINAL 1 --> TERMINAL AIF of A/C control assembly --> TERMINAL GND -->
GROUND
, the motor rotates and the damper moves to the Recirc side. While the damper operates, the damper position signal is input from 
TERMINAL 5 of the servo motor to TERMINAL TPI of the ECU (built into the A/C control assembly).  As a result, current to the servo motor
circuit is cut OFF by the ECU, so the damper stops at that position.

(switching from Recirc to fresh)
With Ignition SW turned ON, when the Recirc/fresh SW is switched to the fresh side, the current flows from TERMINAL IG of A/C control
assembly --> TERMINAL AIF --> TERMINAL 1 of air inlet control servo motor--> TERMINAL 2 --> TERMINAL air of A/C control
assembly --> TERMINAL GND --> GROUND, the motor rotates and the damper stops at that position.

3.

OPERATION OF AIR VENT MODE CONTROL SERVO MOTOR
With Ignition SW tuned ON, the current flows from GAUGE fuse to TERMINAL IG of A/C control assembly.
(switching from DEF to face)
The current flows fromTERMINAL AOF of A/C control assembly TERMINAL 1of air vent control mode servo motor --> TERMINAL 2 -->
TERMINAL ADO
 of A/C control assembly --> TERMINAL GND --> GROUND. The motor rotates and the damper moves to the face side.
While the damper operates, the damper position signal is input from TERMINAL 5 of the servo motor to the TERMINAL TPO of the ECU
(built into the A/C control assembly). As a result, current to the servo motor circuit is cut OFF by the ECU, so the damper stops at that position.

(Switching from face to DEF)
The current flows from TERMINAL AOD  of A/C control assembly --> TERMINAL 2 of air vent mode control servo motor --> TERMINAL 1
--> TERMINAL AOF
 of A/C control assembly --> TERMINAL GND --> GROUND, the motor rotates and the damper stops at that position.

4.

OPERATION OF AIR MIX CONTROL SERVO MOTOR
when the temperature SW is turned to the "cool" side, the current flows from TERMINAL AMC of A/C control assembly --> TERMINAL 1 of
air mix control servo motor --> MOTOR --> TERMINAL 2 --> TERMINAL AMH of A/C control assembly --> GROUND and the motor
rotates. The damper opening angle at this time is input from TERMINAL 5 of servo motor to TERMINAL TP of A/C control assembly, this is
used to determine the damper stop position and maintain the set temperature.

When the temperature control SW is turned to the "warm" side, the current flows from servo motor --> TERMINAL AMH of A/C control
assembly -->  TERMINAL 2 of air mix control servo motor --> MOTOR --> TERMINAL 1 --> TERMINAL AMC of A/C control assembly
rotating the motor in reverse and switching the damper from cool to warm side.

5.

OPERATION OF MAX COOL DAMPER CONTROL SERVO MOTOR
When the mode SW is set to Bi-level, current flows from the GAUGE fuse to TERMINAL 4 of max cool control servo motor--> TERMINAL 1
--> TERMINAL CBLO
 of A/C control assembly -->TERMINAL GND --> GROUND. This operates the motor to set the damper to the max
cool side.

6.

AIR CONDITIONING OPERATION
The A/C control assembly receives various signals, i.e., the Engine RPMfrom the Igniter, outlet temperature signal from the A/C thermistor,
coolant temperature from the Engine coolant temp. Sensor(Water Temp. Sensor) and the lock signal from the A/C compressor, ETC.
When the Engine is started and the A/C SW (A/C Control Assembly) is ON, a signal is input to the ECU (Built in the A/C Control Assembly). As
a result, the GROUND circuit in A/C control assembly is closed and current flows from GAUGE to TERMINAL 1 of A/C magnetic clutch relay 
--> TERMINAL 2 --> TERMINAL ACMG of Engine control module (Engine and Electronically Controlled Transmission ECU) TERMINAL
A/C --> TERMINAL MGC
 of A/C lock amplifier --> TERMINAL 7 --> TERMINAL MGC of A/C control assembly --> TERMINAL GND

Circuit Operation|Page 1136 > < Diagram Information and Instructions|Page 1133