GS 300 L6-3.0L (2JZ-GE) (1993)
Distributor: Service and Repair
REMOVAL
1. Disconnect negative terminal cable from battery.
CAUTION: Work must be started after 90 seconds from the time the ignition switch is turned to the LOCK position and the negative (-) terminal
cable is disconnected from the battery.
High Tension Cords
2. Disconnect distributor connector.
3. Disconnect high-tension cords from distributor.
NOTICE: Pulling on or bending the cords may damage the conductor inside.
Distributor Nut
4. Remove distributor.
-
Remove the nut.
-
Pull out the distributor.
-
Remove the o-ring from the Distributor housing.
DISASSEMBLY
1. Remove the three screws and remove the heat insulator.