lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Catalytic Converter|Specifications|Page 1252 > < Catalytic Converter|Specifications|Page 1250
Page 2
background image

-

Install 2 new gaskets and the No. 2 front exhaust pipe to the exhaust manifolds with 4 new nuts.

Torque:  62 Nm (46 ft lb) 

-

Install the pipe support bracket to the transmission with the 2 bolts.

Torque:  43 Nm (32 ft lb) 

-

Install a new gasket to front end of the front exhaust pipe, and torque the front exhaust pipe to the No. 2 front exhaust pipe.

Torque:  43 Nm (32 ft lb) 

Removal - Rear Catalytic Converter

1. Disconnect Sub Heated Oxygen Sensor from front exhaust pipe (Calfornia only).

-

Disconnect the wire grommet from the floor.

-

Remove the 2 bolts and sensor cover.

-

Disconnect the Oxygen Sensor from the exhaust pipe.

2. Remove front exhaust pipe (rear Converter).

-

Remove the 2 bolts holding the front exhaust pipe to the center exhaust pipe.

-

Remove the 2 bolts and nuts holding the front exhaust pipe to the No.2 front exhaust pipe.

-

Remove the front exhaust pipe and 2 gaskets.

Installation - Rear Catalytic Converter

Catalytic Converter|Specifications|Page 1252 > < Catalytic Converter|Specifications|Page 1250