3. Remove air mix link cover.
(a) Remove 3 screws and the air mix link cover.
4. Remove max cool damper control servomotor.
(a) Remove the clamp and disconnect the shaft.
(b) Disconnect the connector.
(c) Remove 2 screws and the max cool damper control servomotor.
5. Remove air mix damper control servomotor
(a) Remove the clamp and the water valve control cable.
(b) Remove the clamp and disconnect the shaft.
(c) Remove 3 screws and the air mix damper control servomotor.
6. Remove water temperature sensor.
(a) Disconnect the connector.
(b) After pulling off the clamp, pull out the sensor.