Air Flow Meter/Sensor: Description and Operation

Fig.13 - Cutaway View Of Volume Air Flow Meter. Note The Formation Of Vortices Behind The Generating Object.

PURPOSE

The Volume Air Flow Meter accurately measures the amount of air entering the engine.

Fig.12

OPERATION

As shown in the figure, when a pillar (Vortex generating body) is placed in the path of a uniform flow, vortices called Karman-Vortex are
generated downstream of the object. Using this principle, a vortex generator is placed inside the Volume Air Flow Meter. By measuring the
frequency of the vortices generated, the Engine Control Module can determine the volume of air flowing through the Volume Air Flow Meter. The
vortices are detected by their exerting pressure on thin metal foil (mirror) surfaces and a light emitting element and light receptor (LED and photo
transistor) positioned opposite the mirror which optically senses the vibrations in the mirror. The Engine Control Module uses these signals mainly
for calculation of the basic injection volume and the basic ignition advance angle.