4. Inspect the Volume Air Flow Meter.
-
Check that the honey-combed is neither deformed nor damaged. If necessary, replace the Volume Air Flow Meter.
Installation
1. Install Volume Air Flow Meter from air cleaner.
-
Install a new gasket and the Volume Air Flow Meter with the 4 nuts and bolt.
Torque: 10 Nm (7 ft lb)
-
Connect the wire clamp to the bracket.
-
Connect the Volume Air Flow Meter connector.
-
Connect the high-tension cord to the cord clamp.
2. Install air cleaner hose.
-
Install the air cleaner hose with the 2 hose clamps.
-
Connect the power steering air hose to the air cleaner hose.
3. Connect cable from negative terminal of battery.