lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Fuel Injector|Removal|Page 2510 > < Fuel Injector|Removal|Page 2508
Page 5
background image

-

Install the nut holding the Vacuum Switching Valve to the chamber stay.

-

Connect the following connectors:

Sub-Throttle Actuator connector (w/TRAC) (1).
Sub-Throttle Position Sensor connector (w/ TRAC) (2).
Idle Air Control Valve connector (3).
Throttle Position Sensor connector (4).
Vacuum Switching Valve for Exhaust Gas Recirculation connector (5).

-

Connect the following hoses:

Positive Crankcase Ventilation hose to intake air connector (1).
3 vacuum hoses to No. 2 vacuum pipe (2).

9. Install Throttle Body bracket with the 4 nuts.

Torque:  21 Nm (15 ft lb) 

10. Connect Exhaust Gas Recirculation Gas Temperature Sensor connector (California only).

Fuel Injector|Removal|Page 2510 > < Fuel Injector|Removal|Page 2508