GS 300 L6-3.0L (2JZ-GE) (1993)
^
Remove the two screws and cover plate; see figure 1.
Note:
The screws and cover plate are reusable.
^
Pry up the cover plate tab using a small flat-head screwdriver and remove the plate. Use care not to damage the motor housing; see figure 2.
Note:
The cover plate is not reusable.
2.
REMOVE WINDOW REGULATOR DRUM AND WIRE GUIDE FROM MOTOR HOUSING USING NEEDLE NOSE PLIERS (SEE
FIGURE 3).
Caution:
Do not use a flat-head screwdriver to remove the drum and wire guide.
WINDOW REGULATOR INSTALLATION:
1.
INSERT THE WINDOW REGULATOR DRUM INTO THE MOTOR HOUSING.
Note:
^
To prevent the window regulator drum and cable from coming off, do not tilt the drum, subject it to shocks or use force. If the cable comes
off the drum, do not rewind the cable or reuse it. After the window regulator is installed, do not operate it manually (some window
regulators do not utilize a stopper).
^
Multipurpose grease (P/N OO289-1WG00) should be applied to all moving parts, especially inside the motor housing and sides of the
window regulator drum.
Type "A" holding tool