GS 300 RWD V6-3.0L (3GR-FSE) (2006)
6. Add proper amount of ATF to the refill hole.
NOTICE: Refill amount differs depending on the related procedures.
7. Install a new O-ring and the refill plug.
Torque: 39 Nm (400 kgf-cm, 53 ft. lbs.)
8. Lower down the vehicle.
9. Using SST, create a short-circuit between terminals TC and CG of the DLC3.
SST 09843-18040
10. Start the engine.
NOTICE:
^ Be sure to place the key inside the cabin in order to start the engine.
^ Turn the A/C off.
11. Slowly move the shift lever from the P to the S position, shift the gear from 1st to 6th and then return the shift lever to the P position.
12. Switch to the fluid temperature detection mode.
^ Move the shift lever from the N to the D position or from D to N within 1.5 seconds.
^ Perform the above procedure for 6 seconds or more.
Standard: Meter indicator light "D" comes on for 2 seconds and then goes off.
13. Disconnect terminal TC after confirming the above condition.
14. Idle the engine to raise fluid temperature.