^ Move the shift lever from the N to the D position or from D to N within 1.5 seconds.
^ Perform the above procedure for 6 seconds or more. 

Standard: Meter indicator light "D" comes on for 2 seconds and then goes off.

5. Disconnect terminal TC after confirming the above condition.
6. Idle the engine to raise fluid temperature.

7. Lift up the vehicle right after meter indicator light "D" comes on. 

NOTICE:   
^ Add fluid only when the meter indicator light is on.
^ Perform the procedure while the engine is idling.

8. Remove the overflow plug. If ATF overflows, proceed to [*5]. If ATF does not overflow, proceed to [*6] 

HINT: "Overflow" indicates the condition that ATF drains out from the overflow tube.

f.

When fluid overflows: [*5]

1. Install a new gasket and the overflow plug when the draining ATF becomes a trickle. 

Torque: 20 Nm (204 kgf-cm, 15 ft. lbs.)

NOTICE:   Be careful when handing the drained ATF as its temperature is high.