GS 300 RWD V6-3.0L (3GR-FSE) (2006)
c. Remove the 4 nuts, 4 spacers and charcoal canister assembly.
INSTALLATION
1. INSTALL CHARCOAL CANISTER ASSEMBLY
a. Install the charcoal canister and 4 spacer with the 4 nuts.
Torque: 14.7 N.m (150 kgf.cm, 11 ft.lbf)
b. Connect the 2 tubes and hose.
1. Connect the air inlet line tube to the canister (leak detection pump).
2. Connect the vent line tube to the canister filter.
3. Connect the purge line hose.
c. Connect the connector with the 2 clamps.