lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Sensors and Switches - Powertrain Management > < Secondary Injector Control Module|Diagrams|Page 3528
Page 2
background image

-

The injector driver is grounded at the bolt and nut. To ensure that it is grounded, clean all oil and foreign matter from the installation areas of
the injector driver and engine before installing the injector driver.

a. Install the injector driver with the bolt and 2 nuts.

Torque: 10 N.m (102 kgf.cm, 7 ft.lbf)

2. INSTALL NO.1 ENGINE COVER

a. Install the cover with the 3 clips.
b. Connect the 4 connectors.

NOTE:  Clip the connector securely.

3. INSTALL AIR CLEANER INLET

a. Install the air cleaner inlet with the bolt.

Torque: 5.0 N.m (51 kgf.cm, 44 in.lbf)

4. INSTALL COOL AIR INTAKE DUCT SEAL
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
6. PERFORM INITIALIZATION

a. Perform initialization

NOTE:  Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.

Sensors and Switches - Powertrain Management > < Secondary Injector Control Module|Diagrams|Page 3528