lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 3970 > < Diagram Information and Instructions|Page 3968
Page 14
background image

-

The flowchart shows how to proceed with troubleshooting using the DTC check. Directions from the flowchart will indicate how to proceed either
to DTC troubleshooting or to the troubleshooting of each problem symptom.

The problem is still occurring in a place other than the diagnostic circuit (the DTC displayed first is either for a past problem or a secondary
problem).

Symptom Simulation

SYMPTOM SIMULATION

HINT:  The most difficult case in troubleshooting is when no problem symptoms occur. In such a case, a thorough problem analysis must be carried out.
A simulation of the same or similar conditions and environment in which the problem occurred in the customer's vehicle should be carried out. No matter
how much skill or experience a technician has, troubleshooting without confirming the problem symptoms will lead to important repairs being
overlooked and mistakes or delays.

For example:
With a problem that only occurs when the engine is cold or as a result of vibration caused by the road during driving, the problem can never be
determined if the symptoms are being checked on a stationary vehicle or on a vehicle with a warmed-up engine. Vibration, heat or water penetration
(moisture) is difficult to reproduce. The symptom simulation tests below are effective substitutes for the conditions and can be applied on a stationary
vehicle. Important points in the symptom simulation test: In the symptom simulation test, the problem symptoms as well as the problem area or parts
must be confirmed.  First, narrow down the possible problem circuits according to the symptoms. Then, connect the tester and carry out the symptom
simulation test, judging whether the circuit being tested is defective or normal. Also, confirm the problem symptoms at the same time. Refer to the
problem symptoms table for each system to narrow down the possible causes.

a. VIBRATION METHOD: When a malfunction seems to occur as a result of vibration.

1. PART AND SENSOR

Apply slight vibration with a finger to the part of the sensor suspected to be the cause of the problem, and check whether or not the
malfunction occurs.

NOTE:  Applying strong vibration to relays may open them.

2. CONNECTORS

Slightly shake the connector vertically and horizontally.

Diagram Information and Instructions|Page 3970 > < Diagram Information and Instructions|Page 3968