GS 300 RWD V6-3.0L (3GR-FSE) (2006)
a. Using SST, install the sensor to the front exhaust pipe.
b. Pass the sensor connector through the floor panel and install the grommet.
SST 09224-00010
Torque:
40 N.m (408 kgf.cm, 30 ft.lbf) for use with SST
44 N.m (449 kgf.cm, 32 ft.lbf) for use without SST
c. Connect the sensor connector.
2. INSTALL FRONT SEAT ASSEMBLY (for 4WD)
3. CONNECT FRONT SEAT OUTER BELT ASSEMBLY (for 4WD)
4. INSTALL CONSOLE BOX (for 4WD)
5. INSTALL CONSOLE BOX REGISTER ASSEMBLY (for 4WD)
6. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2 of 2WD)
a. Using SST, install the sensor to the front exhaust pipe.
SST 09224-00010
Torque:
40 N.m (408 kgf.cm, 30 ft.lbf) for use with SST
44 N.m (449 kgf.cm, 32 ft.lbf) for use without SST
HINT: Use a torque wrench with a fulcrum length of 300 mm (11.81 in.).
b. Pass the sensor connector through the floor panel and install the grommet.
c. Connect the sensor connector.
d. Install the scuff plate.