GS 300 RWD V6-3.0L (3GR-FSE) (2006)
Battery: Technical Service Bulletins
Electrical - Vehicle Start After Battery Depletion
ELECTRICAL
EL006-05
May 23, 2005
Title:
VEHICLE START AFTER BATTERY DEPLETION
Models:
'06 GS 300 & GS 430
Introduction
In vehicles equipped with the push-button start function, the starting function may not be operational after recharging or while jump-starting a discharged
battery. This condition is most common if battery voltage drops below 9 volts. The following procedure has been developed to address this condition.
Applicable Vehicles
^
2006 model year GS 300 and GS 430 vehicles.
Initialization Procedure
1.
Confirm that the DCC fuse is installed.
NOTE:
If the DCC fuse is not installed, please install it at this time.
2.
Place the shift lever in the "P" position.
3.
Open or close the driver's side door.
NOTE:
This will start an initialization process between the Steering Lock ECU and the Junction Block ECU.