3. Install a new gasket and the overflow plug when the draining ATF becomes a trickle.
Torque: 20 Nm (204 kgf-cm, 15 ft. lbs.)
4. Install a new O-ring and tighten the refill plug.
Torque: 39 Nm (400 kgf-cm, 29 ft. lbs.)
5. Install the transmission case cover with the 2 bolts.
Torque: 5.4 Nm (55 kgf-cm, 48 inch lbs.)
6. Lower the vehicle.
7. Engine switch off and remove the SST
e. When adding a minimum amount of fluid: [*4]
1. Using SST, create a short-circuit between terminals TC and CG of the DLC3.
SST 09843-18040
2. Start the engine.
NOTICE:
^ Be sure to place the key inside the cabin in order to start the engine.
^ Turn the A/C off.
3. Slowly move the shift lever from the P to the S position, shift the gear from 1st to 6th and then return the shift lever to the P position.
4. Switch to the fluid temperature detection mode.