GS 350 RWD V6-3.5L (2GR-FSE) (2007)
Step 54 (Continued)
INSPECTION PROCEDURE
Short to GND In CAN Bus Line
Short to GND in CAN Bus Line
DESCRIPTION
There may be a short circuit between the CAN bus line and +B when there is resistance between terminals 6 (CANH) and 4 (CG) or terminals 14
(CANL) and 4 (CG) of the DLC3.