Condenser HVAC: Service and Repair

REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

HINT: At the time of installation, please refer to the following item.

Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.
Specified amount :600 ± 50 g (21.16 ± 1.76 oz.)

2. REMOVE THESE PARTS:

a. Air cleaner duct
b. Air cleaner assembly
c. 2 radiator upper supports

3. DISCONNECT DISCHARGE HOSE AND LIQUID TUBE

Remove the 2 bolts and disconnect the hose and tube.
Torque: 10 N.m (100 kgf.cm, 7 ft.lbf)

NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.

HINT: At the time of installation, please refer to the following item. Lubricate 2 new O-rings with compressor oil and install them to the hose

and tube.

4. REMOVE CONDENSER

a. Remove the 4 bolts and 2 brackets.
b. Push the radiator toward engine.
c. Push the condenser toward radiator and pull it upward.

Condenser HVAC|Diagrams|Page 7021 > < Condenser HVAC|Diagrams|Page 7019