During ECU flash reprogramming, the Error screen shown may be displayed on the Diagnostic Tester for one of the following reasons: 

1.

Immobilizer key not properly registered or auto-registration mode left open.

2.

Ignition ON/OFF cycling not followed correctly during the flash reprogramming procedure.

3.

The Diagnostic Tester cable is damaged, causing an open communication circuit.

NOTE:

The Diagnostic Tester may operate properly in other modes such as OBD, OBDII, or CARB, with a damaged cable.

To eliminate the possibility of the first 2 reasons causing the error message, do the following:

1.

Confirm the Immobilizer Transponder Master Key is properly registered and auto registration mode is closed. Refer to the Technical Information
System (TIS) and follow the appropriate Repair Manual procedure and consult TSIB SS006-99, "Scantool Immobilizer key Code Utility".

2.

Conduct the ECU flash reprogramming process explicitly following key operation instructions. Refer to TSIB SS001-01, "ECU Flash
Reprogramming Process, "for more details.

To determine if the Diagnostic Tester cable is damaged, follow the test procedures below to check the electrical integrity of the cable. Conduct all
continuity tests with an Ohm meter. For all five continuity test procedures, the resistance values must be below 6.0 ohms to pass.

CABLE TEST 1