GX 470 V8-4.7L (2UZ-FE) (2004)
b. Remove the 9 bolts and stabilizer control w/ bracket valve assy.
13. REMOVE ACCUMULATOR PRESSURE SENSOR WIRE HARNESS
a. Remove the 2 clamps.
b. Disconnect the 2 connectors, disengage the clip and remove the accumulator pressure sensor wire harness.
14. REMOVE STABILIZER CONTROL ACCUMULATOR VALVE TUBE SUB-ASSY
a. Using SST, disconnect the stabilizer control accumulator valve tube.
SST 09023-00100
NOTICE: Do not damage the accumulator valve tube and flare nuts.
b. Disengage the clip and remove the stabilizer control accumulator valve tube.
15. REMOVE STABILIZER CONTROL ADAPTER SUB-ASSY
a. Remove the 2 service valve caps and 2 oil nozzle valves.