GX 470 V8-4.7L (2UZ-FE) (2004)
Torque: 112 Nm (1,140 kgf-cm, 83 ft. lbs.)
34. CONNECT STABILIZER BAR FRONT
35. CONNECT STABILIZER BAR REAR
36. STABILIZE SUSPENSION
a. Lower the vehicle.
1. Place the 4 wheels on the ground with the SST connected.
NOTICE:
^ Pay attention to the SST while lowering the vehicle.
^ Ensure that the jack and lift are completely separated from the vehicle.
b. Set charging pressure to within the specified range.
1. Charge suspension fluid with the SST
Specified charging pressure:
2.60 to 3.00 MPa at 20°C (68°F) (Fluid temperature)
2.90 to 3.40 MPa at 35°C (95°F) (Fluid temperature)
c. Stabilize the vehicle.
1. Do not perform any operations on the vehicle for 30 seconds or more after charging suspension fluid. The vehicle will stabilize during this
time.
37. CHECK SUSPENSION FLUID PRESSURE
a. Check the suspension fluid pressure.
38. MEASURE VEHICLE HEIGHT
Refer to Alignment; Service and Repair.
39. INSTALL ENGINE UNDER COVER SUB-ASSY NO.1
40. INSTALL SPARE DISC WHEEL
41. INSTALL STEP SUB-ASSY LH
42. INSTALL BATTERY
43. INSTALL RADIATOR SUPPORT SEAL UPPER
Stabilizer Control W/Bracket Valve ASSY (KDSS), Disposal
DISPOSAL (KDSS - Kinetic Dynamic Suspension System)
1. DISPOSE OF STABILIZER CONTROL ACCUMULATOR HOUSING ASSY
a. Using a drill, make a hole in the areas between A and B of the accumulator housing indicated in the illustration to discharge the inside gas.
CAUTION:
^
Be careful when drilling because shards of metal may fly about, so always use the proper safety equipment.
^
The gas is colorless, odorless and non-poisonous.