lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Fluid - A/T|Capacity Specifications|Page 3430 > < Fluid - A/T|Capacity Specifications|Page 3428
Page 5
background image

(3) Install a new gasket and overflow plug when the draining ATF becomes a trickle.

Torque: 20 Nm (204 kgf-cm, 15 ft-lbf) 

(4) Install a new 0-ring and refill plug.

Torque: 39 Nm (400 kgf-cm, 29 ft-lbf) 

(5) Lower down the vehicle.
(6) Turn the ignition switch off.

(d) When adding a minimum amount of fluid: (*4)

(1) Using an SST short-circuit between terminals TC and CG of the DLC3.

SST 09843-18040

(2) Start the engine.

NOTICE:  Turn the A/C off.

(3) Slowly move the shift lever from the P to the 2-L position. Return the shift lever to the P position.

(4) Switch to the fluid temperature detection mode.

-

Move the shift lever from the N to the 4D position or from 4D to N within 1.5 seconds.

-

Perform the above procedure for 6 seconds or more.

Standard: Meter indicator lamp "ATF temperature warning lamp" comes on for 2 seconds and then goes off.

(5) Disconnect terminal TC and CG after confirming the above condition.
(6) Idle the engine to increase fluid temperature.

Fluid - A/T|Capacity Specifications|Page 3430 > < Fluid - A/T|Capacity Specifications|Page 3428