GX 470 V8-4.7L (2UZ-FE) (2004)
(3) Install a new gasket and overflow plug when the draining ATF becomes a trickle.
Torque: 20 Nm (204 kgf-cm, 15 ft-lbf)
(4) Install a new 0-ring and refill plug.
Torque: 39 Nm (400 kgf-cm, 29 ft-lbf)
(5) Lower down the vehicle.
(6) Turn the ignition switch off.
(d) When adding a minimum amount of fluid: (*4)
(1) Using an SST short-circuit between terminals TC and CG of the DLC3.
SST 09843-18040
(2) Start the engine.
NOTICE: Turn the A/C off.
(3) Slowly move the shift lever from the P to the 2-L position. Return the shift lever to the P position.
(4) Switch to the fluid temperature detection mode.
-
Move the shift lever from the N to the 4D position or from 4D to N within 1.5 seconds.
-
Perform the above procedure for 6 seconds or more.
Standard: Meter indicator lamp "ATF temperature warning lamp" comes on for 2 seconds and then goes off.
(5) Disconnect terminal TC and CG after confirming the above condition.
(6) Idle the engine to increase fluid temperature.