11. CONNECT WATER HOSE JOINT

a. Connect the water hose joint with the bolt.

Torque: 10 N.m (102 kgf.cm, 7 ft.lbf) 

12. INSTALL INTAKE MANIFOLD

a. Install a new gasket and the intake manifold with the 4 bolts and 4 nuts.

Torque: 21 N.m (214 kgf.cm, 15 ft.lbf) 

b. Connect the SCV position sensor connector.
c. Connect the DC motor connector for the SCV.

13. INSTALL INTAKE AIR SURGE TANK

a. Install a new gasket to the intake air surge tank.
b. Using a 5 mm hexagon socket wrench, install the 6 bolts.

Torque: 
Bolts except A 18 N.m (184 kgf.cm, 13 ft.lbf) 

c. Install the bolt and 2 nuts to the intake air surge tank.

Torque: