lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 253 > < Diagram Information and Instructions|Page 251
Page 7
background image

1. Disconnect connectors A and C and measure the resistance between the terminals of the connectors.

HINT:  Measure the resistance while lightly shaking wire harness vertically and horizontally. If the results match the examples above, an open
circuit exists between terminal 1 of connector and terminal 1 of connector C.

2. Disconnect connector B and measure the resistance between the terminals of the connectors.

If the results match the examples above, an open circuit exists between terminal 1 of connector B2 and terminal 1 of connector C.

c. Check the voltage.

Diagram Information and Instructions|Page 253 > < Diagram Information and Instructions|Page 251