REMOVAL

1. PRECAUTION

CAUTION:  Be sure to read the Restraint Systems Service Precautions thoroughly before servicing.

2. DISCONNECT BATTERY NEGATIVE TERMINAL

CAUTION:  Wait for 90 seconds after disconnecting the cable to prevent airbag deployment.

3. REMOVE FRONT DOOR SCUFF PLATE (w/o Illumination)
4. REMOVE FRONT DOOR SCUFF PLATE (w/ Illumination)
5. REMOVE FRONT DOOR OPENING TRIM COVER RH
6. REMOVE INSTRUMENT SIDE PANEL RH
7. REMOVE NO.2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY
8. REMOVE FRONT PASSENGER SIDE AIRBAG ASSEMBLY
9. REMOVE GLOVE COMPARTMENT DOOR ASSEMBLY

10. DISCONNECT INSTRUMENT PANEL WIRE ASSEMBLY

a. Disconnect the connector.

11. REMOVE INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY

HINT:  Refer to the procedures up to "REMOVE INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY".

12. REMOVE HEATER TO REGISTER NO.3 DUCT
13. REMOVE SIDE DEFROSTER NOZZLE NO.2 DUCT

14. REMOVE FRONT PASSENGER AIRBAG ASSEMBLY

a. Remove the 2 screws.