Variable Valve Timing Actuator: Testing and Inspection
Component Inspection

INSPECTION 

INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY 

a. Measure the resistance between the terminals.

Standard resistance: 6.9 to 7.9 ohms at 20 degrees C (68 degrees F) 

If the result is not as specified, replace the oil control valve.

b. Connect the battery's positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.

If result is not as specified, replace the oil control valve.

NOTE:  If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC may
be output.