IS 350 V6-3.5L (2GR-FSE) (2006)
Knock Sensor: Testing and Inspection
INSPECTION
INSPECT KNOCK SENSOR
a. Measure the resistance between the terminals.
Standard resistance:
120 to 280 kOhms at 20 degrees C (68 degrees F)
If the result is not as specified, replace the sensor.