IS 350 V6-3.5L (2GR-FSE) (2006)
Battery: Technical Service Bulletins
Starting System - Vehicle Start After Battery Depletion
ELECTRICAL
EL016-06
Title:
VEHICLE START AFTER
BATTERY DEPLETION
Models:
'06 GS 300, '06 - '07 GS 430,15 250/350, & '07 ES 350, GS 350, & LS 460
December 22, 2006
Introduction
In vehicles equipped with the Smart Key system, the starting function may not be operational after recharging a discharged battery or jump starting the
vehicle. If battery voltage drops below 9V, the Steering Lock ECU may need to be re-initialized. Follow the initialization procedure below to re-initialize
the Steering Lock ECU.
Applicable Vehicles
^
2006 model year GS 300 vehicles.
^
2006 - 2007 model year GS 430, IS 250, and IS 350 vehicles.
^
2007 model year ES 350, GS 350, and LS 460 vehicles.
Warranty Information
Initialization Procedure
1.
Confirm that the DCC fuse is installed.
NOTE:
If DCC fuse is NOT installed, install at this time.
2.
Place the shift lever in the "P" position.
3.
Open and close the driver's side door.
NOTE:
This will start an initialization process between the Steering Lock ECU and the Junction Block ECU.
4.
Depress the brake pedal.
5.
Press the "START STOP" switch.
6.
Re-initialize any affected power Systems.
^
2006 model year GS 300 or GS 430:
^
Refer to TSIB No. PD009-06, "Power System Initialization During PDS".
^
Refer to TSIB No. PD023-06, "Initial Calibration of Intuitive Parking Assist System".
^
2007 model year GS 350 or GS 430:
^
Refer to TSIB No. PD044-06, "Initialization of Power Window During PDS".