LS 400 V8-4.0L (1UZ-FE) (1990)
Specified torque: 10 N.m (100 kgf.cm, 7 ft.lbf)
-
The tightening torque specified for the bolt used to install the equalizer tube to EPR is shown below.
Specified torque: 10 N.m (100 kgf.cm, 7 ft.lbf)
-
If the evaporator was replaced, add compressor oil to the compressor.
Add 40 - 50 cc (1 .4 - 1.7 fl.oz.)
-
After installation, evacuate the refrigeration system and charge it with refrigerant.
Specified amount: 1,050 g (2.3 lb)
-
After the operation is finished, be sure to check for leakage of refrigerant and check the operation of the A/C.