LS 460 V8-4.6L (1UR-FSE) (2007)
If the resistance is not as specified, replace the starter magnetic switch assembly.
b. Inspect the resistance of the hold-in coil.
1. Measure the resistance between terminal 50 and the switch body.
Standard resistance: Below 2.0 ohms