(1) Cover the sensor installation hole with protective tape cut to a square with a length/width of 25 mm (0.98 in.).
(2) Using a brush or felt, apply primer or equivalent to the retainer installation area.
NOTICE:
-
Use a clean brush or felt.
-
Do not allow primer to contact the front surface of the bumper cover.
(3) Do not touch the bumper cover until the primer has dried.
Recommended drying time:
10 minutes or more (23°C, (73°F))
(4) Confirm that the primer has completely dried by touching the bumper cover. Then remove the protective tape.
(d) Install the 4 No. 1 ultrasonic sensor retainers.
(1) Remove the peeling paper from the retainer.
(2) Insert the sensor tip into the retainer hole area until the claws are attached.
-
Do not touch the adhesive part of the double-sided tape.
-