Steering Angle Sensor: Testing and Inspection
Power Steering System

POWER STEERING: POWER STEERING SYSTEM: CALIBRATION

CALIBRATION

1. ROTATION ANGLE SENSOR VALUE INITIALIZATION AND TORQUE SENSOR ZERO POINT CALIBRATION

NOTE:
Clear the rotation angle sensor calibration value, initialize the rotation angle sensor value, and calibrate the torque sensor zero point if any of
the following has occurred:
-

The power steering ECU has been replaced.

-

The power steering gear assembly has been replaced.

-

Steering effort differs between left and right.

(a) Inspection before calibration.

(1) Connect the Techstream to the DLC3.
(2) Turn the engine switch on (IG).
(3) Turn the Techstream on.

Select "IG Supply" from the data list.

(4) Check the IG power supply voltage on the tester screen.

EMPS

Standard voltage:
11 to 14 V

NOTE:
If the IG power supply voltage is 11 V or less, calibration cannot be performed. In this case, charge or replace the battery, and then perform
calibration.

(b) Clearing rotation angle sensor calibration value, rotation angle sensor value initialization, and torque sensor zero point calibration.

NOTICE:
-

If DTC C1516 (Torque Sensor Zero Point Adjustment Incomplete) is stored, the torque sensor zero point cannot be calibrated. Clear the
DTC before starting calibration.

-

If DTC C1526 (Motor Rotation Angle Sensor Initialization Incomplete) is stored, the rotation angle sensor value cannot be initialized.
Clear the DTC before starting initialization.

(1) Connect the Techstream to the DLC3.
(2) Turn the engine switch on (IG).
(3) Turn the Techstream on.

Select "Torque Sensor Adjustment".

(4) Follow the procedures on the tester display to clear the rotation angle sensor calibration value, initialize the rotation angle sensor value,

and calibrate the torque sensor zero point.

NOTICE:
-

When initializing the rotation angle sensor value, observe the following to stabilize sensor voltage:
After turning the engine switch on (IG), wait for at least 2.5 seconds before turning the steering wheel. Do not turn the steering wheel
quickly.

-

The steering wheel will vibrate during torque sensor zero point calibration. Do not touch the steering wheel while it is vibrating or for 2
seconds after it stops.