lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Ultrasonic Sensor (For Front Side)|Page 10450 > < Ultrasonic Sensor (For Front Side)|Page 10448
Page 5
background image

NOTICE:
*

Do not touch the adhesive part of the double-sided tape.

*

Do not allow foreign matter to contact the adhesive part of the double-sided tape.

(3) Confirm the direction of the connector's connection position. Then insert the tape on the sensor into the sensor installation hole of the

bumper cover, and set the retainer on the bumper cover.

NOTICE:
Do not completely install the retainer at this time.

(4) Remove the tape on the sensor from the front surface of the bumper cover. 0.3 mm (0.0118 in.)

(5) Check if the clearance between the sensor tip and sensor installation hole of the bumper cover is as shown in the illustration. (Check the

entire circumference of the sensor tip.)

HINT
If the clearance is not as specified, adjust the sensor position by moving it vertically and horizontally.

(6) Firmly press the retainer with your hands.

Ultrasonic Sensor (For Front Side)|Page 10450 > < Ultrasonic Sensor (For Front Side)|Page 10448