lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

Components|Page 17 > < Components|Page 15
Page 1
background image

Alarm Module: Service and Repair
Removal

ENGINE IMMOBILIZER: CERTIFICATION ECU: REMOVAL

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.

NOTICE:
*

After the engine switch is turned off, the HDD navigation system requires approximately 6 minutes to record various types of
memory and settings. As a result, after turning the engine switch off, wait 6 minutes or more before disconnecting the cable from
the negative (-) battery terminal.

*

When disconnecting the cable, some systems need to be initialized after the cable is reconnected    See: Testing and
Inspection/Programming and Relearning.

2. REMOVE INSTRUMENT SIDE PANEL LH   See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and

Repair/Removal and Replacement/Removal

3. REMOVE NO. 1 INSTRUMENT CLUSTER MOULDING   See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument

Panel/Service and Repair/Removal and Replacement/Removal

4. REMOVE NO. 1 INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY   See: Body and Frame/Interior Moulding / Trim/Dashboard /

Instrument Panel/Service and Repair/Removal and Replacement/Removal

5. REMOVE CERTIFICATION ECU

(a) Disconnect the 2 connectors.

(b) Remove the nut and ECU.

Components|Page 17 > < Components|Page 15